ȨÀ¸·Î | ȸ¿øµî·Ï | ·Î±×ÀÎ | °í°´¼¾Å¸ | ENGLISH
   
 
ȨÀ¸·Î > ´Ù¿î·Îµå ¸®½ºÆ® > ´Ù¿î·Îµå º¸±â
µî·ÏÀÏ: 2013-01-31
Á¦¸ñ: iSolution DT-M /L ÇÁ·Î±×·¥ for Win7/Vista/WinXP/2000/ME/Win98Se
÷ºÎÆÄÀÏ:  

¿©·¯Â÷·ÊÀÇ update°¡ ÀÖ¾ú½À´Ï´Ù. Update¿¡ °üÇÑ ³»¿ëÀº ÀúÀÇ IMT i-Solution Inc.·Î Á÷Á¢ ¿¬¶ôºÎŹÇÕ´Ï´Ù. imtmike0@gmail.com ȤÀº mikeimt@unitel.co.kr ÀÔ´Ï´Ù.

¸ðµç Á¾·ùÀÇ DT (DT-L, DT, DT-M) ÅëÇÕ ÇÁ·Î±×·¥ÀÔ´Ï´Ù.

ÇÁ·Î±×·¥ update½Ã ±âÁ¸¿¡ ¼³Ä¡µÈ ÇÁ·Î±×·¥À» ¸ÕÀú »èÁ¦ ÇϽñ⠹ٶø´Ï´Ù. »èÁ¦Àü Ķ¸®¹ö·¹ÀÌ¼Ç (Calibration)À» ÆÄÀÏ ÇüÅ·ΠÀúÀå Çϼ̴ÂÁö È®ÀÎ ÇϽñ⠹ٶø´Ï´Ù. ÃøÁ¤ > º¸Á¤ > ¸ðµÎ ÀúÀå ¸í·É¾î¸¦ »ç¿ëÇϽñ⠹ٶø´Ï´Ù.

µ¿±Û (ÇÁ·Î±×·¥ ¶ôÅ°)°¡ ¹Ù²î¾ú½À´Ï´Ù. 2011. 07 ÀÌÀü¿¡ ±¸¸ÅÇÏ½Ã°í ¿¹Àü Å°¸¦ »ç¿ëÇϽô °í°´ºÐµéÀº ¾÷Å×ÀÌÆ®°¡ ÇÊ¿äÇÏ½Ç °æ¿ì ÀúÈñ ¾ÆÀÌ¿¥Æ¼·Î ¿¬¶ôÇÏ¿© Áֽñ⠹ٶø´Ï´Ù.

±¹Á¦±Ô°Ý¿¡ µû¸¥ ÇÊÅÍ Ã»Á¤µµ ºÐ¼® ½Ã½ºÅÛÀÌ Ãß°¡ µÇ¾ú½À´Ï´Ù. ½Ã½ºÅÛ ±¸¼ºÀº Çö¹Ì°æ, Àüµ¿ ½ºÅ×ÀÌÁö, ÇÊÅÍ È¦´õ, Ä«¸Þ¶ó, ÄÄÇ»ÅÍ, DT-M ÇÁ·Î±×·¥ÀÔ´Ï´Ù. ÀÚ¼¼ÇÑ ³»¿ëÀº ÀúÈñ ¾ÆÀÌ¿¥Æ¼·Î ¹®ÀÇ ÇÏ¿© ÁÖ½Ã¸é °¨»çÇÏ°Ú½À´Ï´Ù.

2012.08.08
°¡Àå ÃÖ±Ù ¹öÁ¯Àº 2012.08.08 ¿¡ ¾÷µ¥ÀÌÆ® µÇ¾ú½À´Ï´Ù. °¡Áö°í °è½Å ¹öÁ¯À» È®ÀÎÇϽðí ÀúÈñµé¿¡°Ô ¿¬¶ô Áֽñ⠹ٶø´Ï´Ù.
2012³âµµ¿¡ ¿©·¯¹øÀÇ ¾÷µ¥ÀÌÆ®°¡ ÀÖ¾ú½À´Ï´Ù.

2011. 09.15
1. ¹Ì±¹ ÀÚµ¿Â÷ ȸ»ç (Ford, GM, Chrysler) µéÀÇ »ç³» ±Ô°ÝÀÎ ¿ëÁ¢ÃøÁ¤(Weld measurement)¸¦ Ãß°¡ ÇÏ¿´½À´Ï´Ù.
2. Software¸¦ »ç¿ëÇÑ ASTM ±ÔÁ¤ÀÎ ASTM E1245 ¸¦ Ãß°¡ ÇÏ¿´½À´Ï´Ù. .
3. ÇÊÅÍ Ã»Á¤µµ ºÐ¼® (Filter cleanliness analysis) ±â´ÉÀ» Çâ»ó ½ÃÄ×½À´Ï´Ù. Àüµ¿ ½ºÅ×ÀÌÁö ÀÀ¿ëºÐ¾ßÀÇ ±â´ÉµéÀÌ Ãß°¡, Çâ»óµÇ¾ú½À´Ï´Ù.

2011. 08.20
1. ¼öµ¿ÃøÁ¤½Ã ¶óÀÎÀÇ Ä®¶ó°¡ ÀÚµ¿À¸·Î ¹Ù²î´Â ¿É¼ÇÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù. ÀÌ °æ¿ì °¢ ¶óÀÎÀº º°µµÀÇ Ä®¶ó¸¦ °¡Áö°Ô µË´Ï´Ù. ÆÄÀÏ > ±âº»¼³Á¤ > ÃøÁ¤ > »ö»ó (Ư¡) ¿¡ Àִ ýũ Ç¥½Ã¸¦ ÇØÁ¦(uncheck) ÇÏ½Ã¸é µË´Ï´Ù.
2. Àüüȭ¸é ¸ðµå < º¸±â ¸¦ Ãß°¡ ÇÏ¿´½À´Ï´Ù. ÀÌ °æ¿ì À̹ÌÁö°¡ Àüü È­¸éÀ» ä¿ì°Ô µË´Ï´Ù.
3. ¼öµ¿ÃøÁ¤¿¡ ¼öÆò¼öÁ÷Æø ÃøÁ¤ ±â´ÉÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù. ¼öÆò°ú ¼öÁ÷ÀÇ ÆøÀ» µ¿½Ã¿¡ ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. µð½ºÇ÷¹ÀÌ(Display)¿Í ¹ÝµµÃ¼ °ü·Ã ÀÀ¿ë ºÐ¾ß¿¡¼­ ¾ÆÁÖ À¯¿ëÇÏ°Ô »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

»õ·Î¿î ±â´ÉµéÀÇ »ç¿ë¹æ¹ýÀ» º¸¿©ÁÖ´Â µ¿¿µ»óÀÌ ÀúÈñ À¥»çÀÌÆ® ±â¼úÁö¿ø¿¡ ¿Ã·ÁÁ® ÀÖ½À´Ï´Ù. »ç¿ë¹æ¹ýÀ» ÂüÁ¶ÇÏ¿© Áֽñ⠹ٶø´Ï´Ù. °¨»çÇÕ´Ï´Ù.
2011. 04.12
1. ºñ±Ý¼Ó °³Àç¹° ºÐ¼®¿¡ ±âÁ¸ÀÇ KSD 0204-2002 ¿Ü¿¡ 1982 ³â ±ÔÁ¤ÀÎ KSD 0204-1982 ³â ±ÔÁ¤À» Ãß°¡ ÇÏ¿´½À´Ï´Ù.
2. Graphite cast iron analysis (ÁÖö ±¸»óÈ­ ºÐ¼®) ±â´ÉÀ» Çâ»ó ½ÃÄ×½À´Ï´Ù.

2011. 02. 28
À̹ÌÁö ĸÃÄ ±â´ÉÀ» Çâ»ó ½ÃÄ×½À´Ï´Ù.

2011.02.14
IMT ¸ðµç ÇÁ·Î±×·¥µéÀÌ ´ëÆøÀûÀ¸·Î ¾÷±×·¹ÀÌµå µÇ¾ú½À´Ï´Ù.
1. À̹ÌÁö ĸÃÄ »ç¿ëÀÚ ÀÎÅÍÆäÀ̽º°¡ ´ëÆøÀûÀ¸·Î ¹Ù²î¾ú½À´Ï´Ù. À̹ÌÁö ĸó¿Í ¶óÀ̺ê (Live) ÃøÁ¤, ¶óÀ̺ê (Live) ÃÊÁ¡Çâ»ó, ¿À¹ö·¹ÀÌ (Overlay) ¸ðµÎ¸¦ ÇϳªÀÇ ¸Þ´º À©µµ¿ì¿¡ ¹èÄ¡ÇÏ¿´½À´Ï´Ù. »ç¿ëÀںеéÀº ¼Õ½±°Ô À̹ÌÁö ĸó¿Í ¶óÀ̺ê (Live) ¿µ»ó°ú °ü·ÃµÈ ¸ðµç ±â´ÉµéÀ» ÇϳªÀÇ Ã¢¿¡¼­ ´Ù·ê ¼ö ÀÖ°Ô µÇ¾ú½À´Ï´Ù.
2. ¶óÀ̺ê (Live) ÃøÁ¤°ú ¶óÀ̺ê (Live) ÃÊÁ¡Çâ»ó ¿¡¼­µµ Ä«¸Þ¶ó ¼³Á¤À» ÀÚÀ¯·Ó°Ô Á¶Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
3. ÇÁ·Î±×·¥ ÁÖ ¸Þ´º ¾ÆÀÌÄܵéÀ» Ä®¶ó·Î ¹Ù²Ù¾ú½À´Ï´Ù.
4. ÃøÁ¤ÀÇ Á¤¹Ðµµ¸¦ ȹ±âÀûÀ¸·Î Çâ»ó½ÃÄ×½À´Ï´Ù. Çȼ¿ ÇÑ °³ÀÇ ´ÜÀ§·Î ÃøÁ¤ À§Ä¡¸¦ Á¶ÀýÇÒ ¼ö°¡ ÀÖ½À´Ï´Ù. ¸¶¿ì½º·Î Á¤È®ÇÑ À§Ä¡¸¦ ÁöÁ¤Çϱâ´Â ¾î·Æ½À´Ï´Ù. ´õ±¸³ª Çȼ¿ ÇÑ °³ÀÇ ´ÜÀ§·Î ÃøÁ¤ À§Ä¡¸¦ Á¶ÀýÇÏ´Â °ÍÀº ºÒ°¡´É ÇÕ´Ï´Ù.ÃøÁ¤½Ã Å°º¸µåÀÇ È­»ìÇ¥ Å°¸¦ »ç¿ëÇϸé, Çȼ¿ ÇÑ °³ ´ÜÀ§·Î ¿òÁ÷ÀÌ°Ô ÇÒ ¼ö ÀÖ½À´Ï´Ù. º¸±â ¸Þ´ºÀÇ È®´ëâ ±â´ÉÀ» »ç¿ëÇϽñ⠹ٶø´Ï´Ù. ±×¸®°í ÃøÁ¤ ½ÃÀÛÁ¡ À§Ä¡¸¦ ¸¶¿ì½º¿Í Å°º¸µå È­»ìÇ¥ Å°¸¦ »ç¿ëÇÏ¿© Çȼ¿ ÇÑ °³ ´ÜÀ§·Î Á¤È®È÷ ÁöÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. ¸¶¿ì½º Ŭ¸¯ ȤÀº Å°º¸µåÀÇ ¿£ÅÍÅ°·Î¼­ ½ÃÀÛÇÕ´Ï´Ù.
5. ÃøÁ¤½Ã ÁöÁ¤µÈ À̸§À» ÀÓÀÇ·Î ¹Ù²Ü ¼ö ÀÖ½À´Ï´Ù. ¿¹·Î¼­ Á÷¼± ÃøÁ¤½Ã À̸§ÀÌ L1, L2, L3·Î Ç¥±âµÇ´Â ´ë½Å ÀÓÀÇ·Î Á¤ÇÑ À̸§, ÀÓÀÇÀ̸§1, ÀÓÀÇÀ̸§2, ÀÓÀÇÀ̸§3 µîÀ¸·Î ¹Ù²Ù¾î Ç¥±âµÇ°Ô ÇÒ ¼ö ÀÖ½À´Ï´Ù.
6. Live ÃÊÁ¡ ±â´ÉÀ» º¸´Ù ´õ Çâ»ó ½ÃÄ×½À´Ï´Ù. »ç¿ëÇÏ¿© º¸½Ã±â ¹Ù¶ø´Ï´Ù.
7. »ç¿ëÀÚ°¡ ÀÌ¹Ì ¸¸µé¾îµÐ ¿¢¼¿ ÅÛÇø´ ¾ç½ÄÀ¸·Î ¿øÇÏ´Â À§Ä¡¿¡, ÇÊ¿äÇÑ µ¥ÀÌÅ͸¸ Àü¼ÛÇÒ ¼ö ÀÖ½À´Ï´Ù. »ç¿ëÀÚÀÇ º¸°í¼­ ¾ç½Ä¿¡ ÀÚµ¿À¸·Î ÇÊ¿äÇÑ µ¥ÀÌÅÍ°¡ ä¿öÁö°Ô µË´Ï´Ù.
8. º¸Á¤ (Calibration) À̸§ÀÇ À§Ä¡¸¦ ¸¶¿ì½º µå·¢À¸·Î ¿øÇÏ´Â À§Ä¡¿¡ Àç¹èÄ¡ ÇÒ ¼ö ÀÖ½À´Ï´Ù. »õ·Î¿î º¸Á¤ (Calibration) À» Ãß°¡ÇÒ °æ¿ì Ãß°¡µÈ º¸Á¤ (Calibration) À̸§À» ¿øÇϽô À§Ä¡¿¡ Àç¹èÄ¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
9. iSolution DT¿¡ Live particle analysis ±â´ÉÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù. ´ÜÀ§ ¸éÀû´ç ParticleÀÇ °³¼ö¿Í Æò±Õ Á÷°æÀÌ Live È­¸é »óÅ¿¡¼­ ÀÚµ¿À¸·Î Ç¥±â°¡ µË´Ï´Ù.
10. ´Ù¾çÇÑ Carbon steel ±×·¹ÀÎ »çÀÌÁî ÃøÁ¤À» À§ÇÏ¿© ±×·¹ÀÎ Å׵θ®¸¦ ÁöÁ¤ÇÏ´Â ¿É¼ÇÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù. ´Ù¾çÇÑ ÀçÁúÀÇ °­Á¶Á÷ ±×·¹ÀÎ ÃøÁ¤¿¡ ÀÌ¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

December 24, 2010
1.µ¶ÀÏ Excel »ç¿ëÀÚµéÀ» À§ÇÏ¿© Export to Excel ±â´ÉÀ» Á¶Àý, Çâ»ó ½ÃÄ×½À´Ï´Ù. µ¶ÀÏ (German) ExcelÀº ¿µ¾î Excel°ú Á¶±Ý ´Ù¸¥ ³»ºÎ ±¸Á¶¸¦ °¡Áö°í ÀÖ½À´Ï´Ù. µ¶ÀÏ Excel »ç¿ëÀںеéÀº ÃÖ±Ù ¾÷µ¥ÀÌÆ® ¹öÀüÀ» »ç¿ëÇϽñ⠹ٶø´Ï´Ù.
2.NMI (nonmetallic inclusions) ºÐ¼®¿¡¼­ A type (Sulfide) °ú C type (Silicate)Àº ÀÌ·ÐÀûÀÎ ±¸ºÐ°ú´Â ´Ù¸£°Ô ½ÇÁ¦·Î´Â ÇüÅ°¡ Å©±â°¡ ºñ½ÁÇÑ À̹ÌÁöµéÀ» º¸¿© ÁÝ´Ï´Ù. ¼ººÐºÐ¼®À» °ÅÄ£ ½ÇÁ¦ÀÇ À̹ÌÁöµé ÇüŸ¦ ±âÁØÀ¸·Î ¾Ë°í¸®ÁòÀ» ÀçÁ¶Á¤ ÇÏ¿´½À´Ï´Ù. ±¸ºÐÀÇ ±âÁØÀ» º¸´Ù ´Ù¾çÇÏ°Ô ÇÒ ¼ö ÀÖ´Â ¿É¼Çµµ Ãß°¡ ÇÏ¿´½À´Ï´Ù. NMI A type°ú C type ÀÇ ±¸ºÐÀ» ¸¹ÀÌ ÇϽô »ç¿ëÀںеéÀº ÃֽŠ¹öÀüÀ» »ç¿ëÇϽñ⠹ٶø´Ï´Ù.
3.¼öÆòÁ÷¼±°ú ¼öÁ÷Á÷¼± ¾ÆÀÌÄÜÀ» ¼öµ¿ÃøÁ¤ µµ±¸¸ñ·Ï¿¡ µðÆúÆ®(Default)·Î¼­ ¾ðÁ¦³ª Ç¥½Ã µÇ°Ô ÇÏ¿´½À´Ï´Ù. »ç¿ëÇÏ´Â ºóµµ°¡ ³ôÀº °ÍÀ¸·Î ÆľÇÀÌ µÇ¾î¼­ ¾ðÁ¦³ª º¸À̵µ·Ï ÀçÁ¶Á¤ ÇÏ¿´½À´Ï´Ù. À¯¿ëÇÑ ±â´ÉÀÌ´Ï »ç¿ëÇÏ¿© º¸½Ã±â ¹Ù¶ø´Ï´Ù.

December 10, 2010
1. ½Ç½Ã°£ ÃÊÁ¡Çâ»ó (Live focus enhancement) ±â´ÉÀÌ Ãß°¡ µÇ¾ú½À´Ï´Ù. »ç¿ëÀÚ´Â ½Ç½Ã°£ ¹Ì¸®º¸±â â¿¡¼­ ´Ü¼øÈ÷ Çö¹Ì°æ Z Ãà (Focus knob) À» ¿òÁ÷À̱⸸ ÇÏ¸é µË´Ï´Ù.
»ç¿ëÀÚ´Â ½ºÅ×ÀÌÁö¸¦ ¿òÁ÷À̸鼭 ºü¸£°í Æí¸®ÇÏ°Ô ½Ã·áÀÇ ¿©·¯ À§Ä¡¿¡¼­ ½Ç½Ã°£ ÃÊÁ¡Çâ»ó°ú ½Ç½Ã°£ ÃøÁ¤À» ÇÒ ¼ö ÀÖ°Ô µË´Ï´Ù. ¿Ï¼ºµÈ À̹ÌÁö´Â Clone image ȤÀº Excel·Î º¸³»±â ¸í·ÉÀ¸·Î ÀúÀå ó¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
2. Angle between two lines ÃøÁ¤ µµ±¸¿¡¼­ ²ÀÁþÁ¡ÀÌ ³ªÅ¸³ª°Ô ÇÏ¿´½À´Ï´Ù.
»ç¿ë¹æ¹ýÀº ¸ÕÀú ¼öµ¿À¸·Î µÎ°³ÀÇ Á÷¼±À» ±×¸³´Ï´Ù. ±×·¯°í ³ª¼­ Angle between two lines ´ÜÃ߸¦ Ŭ¸¯ÇÕ´Ï´Ù. ±âÁ¸¿¡ ±×·ÁÁø µÎ Á÷¼± ¶óÀÎ Áß Çϳª¸¦ ¸¶¿ì½º Ŭ¸¯À¸·Î ¼±ÅÃÇÕ´Ï´Ù. ±×¸®°í Control Å°¸¦ ´©¸¥ »óÅ¿¡¼­ ³ª¸ÓÁö ¶óÀÎÀ» ¼±Åà ÇÕÀÌ´Ù.

November 17, 2010
1.Á÷¼± ±æÀÌ ÃøÁ¤ ¹æ½ÄÀÌ µÎ°¡Áö·Î ¹Ù²î¾ú½À´Ï´Ù. ±âÁ¸ÀÇ Å¬¸¯ ±×¸®°í µå·¢ ¹æ½Ä°ú µÎ¹ø ¸¶¿ì½º Ŭ¸¯ ¹æ½ÄÀÌ ÀÖ½À´Ï´Ù. ÀÌ°æ¿ì Á¡¼±À» µû¶ó¼­ ÃøÁ¤°ªÀÌ ½Ç½Ã°£À¸·Î º¸¿© Áý´Ï´Ù. »ç¿ëÀںеéÀº ¾çÂÊ´Ù ¼±ÅÃÀûÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
2. ¿Ïº®ÃÊÁ¡ Çâ»ó ±â´ÉÀÇ ¸Þ¸ð¸® »ç¿ëÀ» ÃÖÀûÈ­ ÇÏ¿´½À´Ï´Ù. ±âÁ¸ »ç¿ë ¸Þ¸ð¸®ÀÇ 1/2·Î ÀÛ¾÷ÀÌ °¡´ÉÇÏ°Ô ÇÏ¿´½À´Ï´Ù. ¿Ïº® ÃÊÁ¡ Çâ»óÀº ÀϹÝÀûÀÎ ºü¸¥ ÃÊÁ¡ Çâ»ó ±â´É¿¡ ºñÇÏ¿© ÈξÀ º¹ÀâÇÑ ¾Ë°í¸®ÁòÀ» »ç¿ëÇÏ°í ÀÖ½À´Ï´Ù. ³»ºÎÀûÀΠó¸® ´Ü°èµµ ÈξÀ ¸¹°í º¹Àâ ÇÕ´Ï´Ù. °¢ ó¸® ´Ü°è¿¡´Â Ãß°¡ÀûÀÎ ¸Þ¸ð¸®¸¦ ÇÊ¿ä·Î ÇÕ´Ï´Ù. 10MP ÀÌ»óÀÇ °íÇØ»óµµ Ä«¸Þ¶ó (DSLR Ä«¸Þ¶ó Æ÷ÇÔ) ¿Í 15 Àå ÀÌ»óÀÇ À̹ÌÁö¸¦ ¿Ïº® ÃÊÁ¡ Çâ»óÀ» À§ÇÏ¿© »ç¿ëÇϽŴٸé, ÃÖ±Ù ¹öÁ¯À» »ç¿ëÇϽñ⠹ٶø´Ï´Ù. ¸Þ¸ð¸® »ç¿ëÀ» º¸´Ù ´õ ÃÖÀûÈ­ ÇÏ¿´½À´Ï´Ù.
3. MS Office 2010 »ç¿ëÀںеéÀº ÃÖ±Ù ¹öÁ¯À» »ç¿ëÇϽñ⠹ٶø´Ï´Ù. ¿¢¼¿·ÎÀÇ µ¥ÀÌÅÍ Àü¼ÛÀÌ º¸´Ù ¾ÈÁ¤ÀûÀÌ°í ÈξÀ ºü¸¨´Ï´Ù. MS Office 2010 À» Click-to-Run ¹æ½ÄÀ¸·Î ¼³Ä¡ Çϼ̴ٸé, ±âÁ¸ Click-to-Run ¼³Ä¡¸¦ Áö¿ì½Ã°í, ÀüÅëÀûÀÎ ¹æ½ÄÀÇ ¸ðµç ÆÄÀÏ ¼³Ä¡·Î ´Ù½Ã ¼³Ä¡ ÇϽñ⠹ٶø´Ï´Ù. Click-to-Run ¼³Ä¡ ¹æ½ÄÀº ÀϺΠÆÄÀϸ¸ ¼³Ä¡°¡ µÇ¾î ¿¢¼¿ ¿¬µ¿ÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù. ÀÏÁ¾ÀÇ °¡»ó ÇÁ·Î±×·¥ ¼³Ä¡ ¹æ½ÄÀ¸·Î ÇÁ·Î±×·¥Àº Á¸ÀçÇϳª, ÆÄÀÏÀÌ ¾ø½À´Ï´Ù.

November 10, 2010
MS Office 2010 ¹öÁ¯À» »ç¿ëÇϽô ºÐµéÀº UpdateµÈ ÇÁ·Î±×·¥À» »ç¿ëÇϽñ⠹ٶø´Ï´Ù. MS Office 2010 ¹öÁ¯¿¡ ¸ÂÃß¾î º¸´Ù ¾ÈÁ¤ÀûÀÌ°í µ¥ÀÌÅÍ°¡ ºü¸£°Ô Àü¼ÛµÇµµ·Ï À籸¼º ÇÏ¿´½À´Ï´Ù. MS office 2007 °ú ÀÌÀü ¹öÁ¯À» »ç¿ëÇϽô ºÐµéÀº updateµÈ ÇÁ·Î±×·¥ ȤÀº ¿¹Àü ÇÁ·Î±×·¥ ¾î´ÀÂÊÀ» »ç¿ëÇϽþ ¹«¹æÇÕ´Ï´Ù.

November 4, 2010
1. DAS (Dendrite arm spacing)-ARP1947 ÀÌ Ãß°¡ µÇ¾ú½À´Ï´Ù.
2. ȸÁÖö Graphite type A, B, C, D, E ºÐ·ù°¡ Ãß°¡ µÇ¾ú½À´Ï´Ù.
3. KSD4302 È濬±¸»óÈ­ ºÐ¼®¿¡¼­ ÃÖÁ¾°ª ÀÌ¿Ü¿¡ n1, n2, n3, n4ÀÇ ±âÃÊ dataµµ °°ÀÌ Ç¥½Ã°¡ µË´Ï´Ù.
4. ÁÖöºÐ¼® Ferrite, Pearlite, Graphite ·®ÀÌ ¸¶¿ì½º Çѹø Ŭ¸¯À¸·Î ÀÚµ¿À¸·Î ÃøÁ¤ÀÌ µË´Ï´Ù.
5. ºñ±Ý¼Ó°³Àç¹° ºÐ¼®¿¡¼­ ûÁ¤µµ ¼öÄ¡ Ci °ªÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù.
6. Excel Àü¼Û±â´ÉÀ» Çâ»ó ½ÃÄ×½À´Ï´Ù. ±âÁ¸ sheet¿¡ Àü¼ÛÇϰųª New sheet¿¡ Àü¼ÛÇÒ ¼ö ÀÖ½À´Ï´Ù.

Sep 16, 2010
Ver9.2 ¿¡¼­¸¸ ¹ß°ßµÈ Excel·Î Àü¼Û½Ã, ÀϺΠÅë°è Âø¿À¸¦ ¼öÁ¤ÇÏ¿´½À´Ï´Ù.
Ver9.2 »ç¿ëÀںеéÀº »õ·Î¿î Ver9.3À» »ç¿ëÇϽñ⠹ٶø´Ï´Ù.

July 21, 2010
À̹ø update´Â »ç¿ëÀÚ Æí¸®¿Í ÃøÁ¤ÀÇ Á¤È®µµ¸¦ ³ôÀÌ´Â °Í¿¡ ÃÊÁ¡À» ¸ÂÃß¾ú½À´Ï´Ù.
Åø¹Ù À§Ä¡¿¡¼­ ¿À¸¥ÂÊ ¸¶¿ì½º¸¦ Ŭ¸¯Çϸé, Åø¹Ù¿¡ ÃøÁ¤ ¾ÆÀÌÄܵéÀ» Ãß°¡Çϰųª Á¦°ÅÇÒ ¼ö ÀÖ½À´Ï´Ù

1. F8 ´ÜÃàÅ°·Î Select feature¸¦ È°¼ºÈ­ÇÒ ¼ö ÀÖ½À´Ï´Ù. »ç¿ëÀںеéÀº ÃøÁ¤ÈÄ ¼öÁ¤½Ã ÇÊ¿äÇÑ Select feature ¸í·ÉÀ» ¸¶¿ì½º·Î Ŭ¸¯Çϰųª F8 ´ÜÃàÅ°¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ¸¶¿ì½º¸¦ ¿òÁ÷ÀÌ´Â °Å¸®¿Í ½Ã°£À» ´ÜÃàÇÒ ¼ö ÀÖ½À´Ï´Ù.
2. Shift key¸¦ »ç¿ëÇϽøé, ÃøÁ¤ ¼öÁ¤½Ã¿¡µµ ¶óÀÎÀÌ ¼öÆò, ¼öÁ÷, 45µµ °¢µµ·Î¸¸ ¿òÁ÷ÀÌ°Ô µË´Ï´Ù.
3. ÃøÁ¤ ¿É¼Ç¿¡ ±ÛÀÚü Ç׸ñÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù. ÃøÁ¤ ¿À¹ö·¹ÀÌ ±ÛÀÚ¿¡¼­µµ ´Ù¾çÇÑ ±ÛÀÚü¸¦ ¼±ÅÃÇÒ ¼ö ÀÖ½À´Ï´Ù.
4. ´Ù¼±Æø ÃøÁ¤
ÀÚµ¿ °æ°è¼± °ËÃâ±â´É°ú ÇÔ²² ¼±ÆøµéÀ» ÀÚµ¿À¸·Î ÃøÁ¤ÇÕ´Ï´Ù.

April 21st, 2010
1. ¼öµ¿ÃøÁ¤½Ã H ÇüÅÂÀÇ ¿À¹ö·¹ÀÌ ¶óÀÎÀÌ ³²¾ÆÀÖ½À´Ï´Ù.
2. ¼±Æø ÀÚµ¿ÃøÁ¤ ±â´ÉÀÌ Ãß°¡ µÇ¾ú½À´Ï´Ù. »ç¿ëÀÚ°¡ ÀÓÀÇ·Î À§Ä¡ÇÒ ¼ö ÀÖ´Â ±âÁؼ± À§¿¡ °É¸®´Â ¸ðµç ¼±ÆøÀÌ ÀÚµ¿À¸·Î ÃøÁ¤ µË´Ï´Ù.

April 17th, 2010
¼±Æø ÀÚµ¿ÃøÁ¤ ±â´ÉÀÌ Ãß°¡ µÇ¾ú½À´Ï´Ù. »ç¿ëÀÚ°¡ ÀÓÀÇ·Î À§Ä¡ÇÒ ¼ö ÀÖ´Â ±âÁؼ± À§¿¡ °É¸®´Â ¸ðµç ¼±ÆøÀÌ ÀÚµ¿À¸·Î ÃøÁ¤ µË´Ï´Ù.

April 5th, 2010
µ¿±Û (key) µå¶óÀ̺갡 update µÇ¾ú½À´Ï´Ù. ³ª¸ÓÁö ±â´ÉµéÀº ÀÌÀü°ú °°½À´Ï´Ù.

Mar.16th, 2010
1. Intensity mean °ú mode parameter°¡ Ãß°¡ µÇ¾ú½À´Ï´Ù.
2. Banding analysis ASTM E1268 ÀÌ DT-M¿¡ Ãß°¡ µÇ¾ú½À´Ï´Ù.
3. Motorized control stage¿¡ »õ·Î¿î ±â´ÉÀÌ DT-M¿¡ Ãß°¡ µÇ¾ú½À´Ï´Ù.

Feb. 19th, 2010
1. ¿¢¼¿·Î º¸³»±â ±â´ÉÀ» ÅëÇÕÇÏ¿´½À´Ï´Ù. ¿øº» À̹ÌÁö¿Í ÃøÁ¤ÇÑ ¿À¹ö·¹ÀÌ À̹ÌÁö°¡ °°ÀÌ È¤Àº µû·Îµû·Î ³Ñ¾î °©´Ï´Ù. À̹ÌÁö Å©±â´Â ÇÁ¸°Æ® »çÀÌÁî·Î ÀÚµ¿ Á¶Àý µË´Ï´Ù. »ç¿ëÀÚ°¡ ¿¢¼¿ ¾ç½ÄÀ» ¸¸µé¼ö ÀÖ½À´Ï´Ù. ·Î°í¸¦ ³Ö°í Á¦¸ñ°ú ¸®Æ÷Æ® ¾ç½Ä¿¡ ÇÊ¿äÇÑ ³»¿ëµéÀ» »ç¿ëÀÚ°¡ Á÷Á¢ ŸÀÌÇÎ ÇÒ ¼ö ÀÖ½À´Ï´Ù. À̾ç½ÄÀº ´Ù½Ã »ç¿ëÇÒ ¼ö ÀÖµµ·Ï ÆÄÀÏ ÇüÅ·ΠÀúÀåµË´Ï´Ù.
2. ROI ¿­±â¸¦ ¸ÅÅ©·Î(macro)¿¡ Ãß°¡ ÇÏ¿´½À´Ï´Ù. °°Àº ¿µ¿ªÀÇ Çü±¤ À̹ÌÁö intensity ÃøÁ¤¿¡ À¯¿ëÇÕ´Ï´Ù. µ¿¿µ»ó ÃøÁ¤¿¡ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
3. ºÐ·ù (Classification) ³»¿ëµµ °°ÀÌ ¿¢¼¿·Î Àü¼Û µË´Ï´Ù.
4. ºÐ·ù ³»¿ëÁß Class º°·Î ÃÖÀú (Low limit), ÃÖ´ë(High limit) °ªÀÌ °°ÀÌ Ç¥½Ã µË´Ï´Ù. ÀÌ ³»¿ë ¿ª½Ã ¿¢¼¿·Î °°ÀÌ Àü¼Û µË´Ï´Ù.

January 11th, 2010
The existing iSolution DT users before 2010 require not using new setup file.
By the same setup file named DT, there are two different programs (DT-L and DT-M) are activated based on the different dongles.
DT-L is the lite version of iSolution DT having major metallurgical functions. It does not support motorized stage control.
DT-M has full features with motorized stage control. It focuses on automatic image analysis applications.
If you are the existing user before 2010, please do not use this setup file.

When upgrade software, be sure to save the already made calibration as a file if you did not save the calibration yet. The command of "Measure > Calibration > Save all" can be used to save the calibration as a file. Later you can open it by the command of "Measure > Calibration > Open".

December 29th, 2009
Capture driver is updated for PixeLINK camera.
New Capture Drivers which is in the DOWNLOADS of the same IMT web is required using the latest programs together.
When updating Capture Drivers, please be sure to update program, too.

December 19
Progam icon and toolist are made with 3D style.

December 7
Refreshed to support multi languages

November 28th, 2009
Win7 support
For 64 bit OS, there is 64 bit dongle driver in the DOWNLOADS of the same IMT web. Please use the 64 bit dongle driver when using 64 bit OS.

November 20th
Refreshed for the updated Data Collector and Macro functions.

October 23rd
Japanese language support is updated.

September 4th, 2009
1. Time stamping is added in all IMT program.
2. The real calibrated image size is seen on the program status bar.
3. Advanced fluorescence function is added in i-Solution and iSolution DT.
4. Z-depth measurement is added in iSolution DT.

August 4th, 2009
Z depth measurement setting is displayed by simple one mouse click.
The real calibrated image size is seen in status bar.

July 9th, 2009
Z depth measurement is added in iSolution DT.
From X and Y axis, sectioned aspect can be measured.
Supporting motorized Z focus units are Marzhauser, Ludl, Prior Scientific, and ASI (Applied Scientific Instrumentation).
Attached video clip shows how to use Z depth measurement function.
Please enjoy new feature and let me know if there is any question.

June 10th, 2009
Version 8.8 is released.
Advanced fluorescence image merge function is added.

June 4th, 2009
1.Full screen preview mode is added in the image capture window.
2. Calibration is still protected by unexpectedly opening and closing calibration file both with password and without password.

March 17th, 2009
Refreshed to support multi language

February 27th, 2009
1. Logo can be inserted when export to Excel in Data Collector menu.
2. Workflow menu is added in Measure. It is really a nice feature to first software user of i-Solution and iSolution DT. I am really like to recommend using new feature.
As usual, all updated software are in the DOWNLOADS of IMT web, www.imt-digital.com. Please remove the existing version after saving Calibration as a file and then install new version.
Thanks again for using IMT software!

February 7th, 2009
1. Program is updated with having Irregular Diameter measurement.
2. Hand tool is also added.
3. For all kinds of coating thickness measurement, several new parameters are added.
For the object being placed horizontally, Min Chord Y, Max Chord Y, Average Chord Y, and Standard Deviation Chord Y can be used.
For the object being placed vertically, Min Chord X, Max Chord X, Average Chord X, and Standard Deviation Chord X can be used.
For the object having irregular shape and being placed on any location such as irregular Arc, Min Chord Free, Max Chord Free, Average Chord Free, and Standard Deviation Chord Free can be used.

January 27th, 2009
1. Refreshed for the better support of motorized stage application.
2. Microindentation hardness test is added.

December 26th, 2008
Microindentation hardness measurement by Knoop and Vickers is added.

November 25th, 2008
Twinned grain comparison is added in the Chart Navigator.

November 12th, 2008
Canon EOS cameras are supported

November 7th, 2008
Image stitching by motorized control stage can be made with the function of Focus Enhancement (Extended focus, Multi-focus, whatever it said) together.
The pictures taken by stereo microscope can also be used for the image stitching by motorized control stage. All taken pictures are aligned automatically while making one stitched image.

October 30th, 2008
1. Line thickness and font size in Measurement has two different options for Visibility and Apply to image.
2. Line thickness option for both Visibility and Apply to image is added in the Grain visual settings of Grain intercept counting settings.

October 21st, 2008
Refreshed to meet a standard in Rust Analysis.

October 17th, 2008
1. Added new function named Run macro for each frame in Acquire X/Y sequence menu which is used for the motorized control stage applications.
All procedures in measurement and date collector menu are recorded as a macro, which can be used together with image stitch function by motorized control stage. One can get analysis data together with perfectly stitched image.

October 1st, 2008
1. Focus enhancement for stereo microscope gives better quality image. The processing procedure step became simpler as one mouse click.
2. In iSolution DT, the below three more metallurgical functions are added.
1) FERRITE DETERMINTAION ON STAINLESS STEEL SECTION
ASTM E562 - 5 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count
2) Rust Analysis
ASTM D610 - 08 Standard Practice for Evaluating Degree of Rusting on Painted Steel Surfaces
JIS H 8681 - 2 Test methods for corrosion resistance of anodic oxide coatings on aluminium and aluminium alloys.

August 8th, 2008
The number of images are calculated automatically in motorized image stitching. Once defining the starting point on the image stitching and the ending point, and then have the software do everything in between.

July 31st, 2008
- Auto calibration adjustment by camera resolution is added. User does not need to make calibration for every camera resolution with that option. Calibration is adjusted automatically depending on the camera resolution.
So once calibration is done for each objective lens, user does not have to concern about the camera capture resolution anymore. Calibration is adjusted automatically.
This function is useful to the user who has a digital camera having many different capture resolutions.
- Illuminator control menu is added. Currently X-Cite from Exfo company illuminator is supported.

July 14th, 2008
The processing speed of phase analysis in iSolution DT is enhanced.

July 7th, 2008
Just refreshed for NMI analysis function.

July 2nd, 2008
Data collector now supports point counting (manual tag) also.
Let's say counting 10 or 20 different object types and mark hundreds of each on the screen. Then move to a different field and do. The same adding the data together as they go.
Then end up with a summary of the different counts into say 20 different channels representing different object types.

June 19th, 2008
Motorized image stitching function is updated. Software auto focus function is added. Right focus can get automatically while scanning whole specimen by motorized stage without using additional hardware for auto focus.

June 6th, 2008
In case there are more than two saved calibration files, the previous calibration is removed when next calibration file is opened. A question, "Would you like to remove all existent calibrations before loading from the file?", is asked when saved calibration file is opened. "Yes" means removing all previous calibrations and
"No" means keeping the previous calibrations with new ones together.

May 15th, 2008
When upgrade, please remove the previous version before installing new version while unplugging dongle from USB port. Please do not forget saving Calibration as a file beforehand if you have not saved the calibration yet.
Dongle is the very what you purchased, do not lose it, please!

Particle analysis module is added as a built-in macro in both i-Solution and iSolution DT.
You can edit the script and data collector file for your own standard.
Under Vista the path is \Users\Public\Documents\IMT\iSolution or iSolution DT\Scripts or DataCollector.
Under WinXP the path is \Documents and Settings\All users\Documents\IMT\ iSolution or iSolution DT\Scripts or DataCollector.
Two video clips showing how to use the function are in the same location of 밆OWNLOADS�.
Particle analysis is made very well and it is a useful feature for many users.
I hope you also try it.

April 16th, 2008
A built- in macro named 밪hortCut� is added in both i-Solution and i-Solution DT.
After image process and measurement, overlay is burned on the image which is made by 밶pply vector� command. Such overlay burned image is ready to be saved by the already assigned file name according to year/month/day and hour/minute/second just like 20080416_085103. All the above procedure is done automatically by the simple mouse click of the built-in macro named 밪hortCut�.

March 15th, 2008
Password in image capture is modified to protect camera resolution only by Format. Camera setting such as exposure can be changed regardless of the password. Only camera resolution is protected by password.

March 14th, 2008
Prior motorized Z-focus unit driver is added.

March 1oth, 2008
It is just a refreshed version which supports some computers which have VISTA security issue. All other things are the same as before.

March 3rd, 2008
1. Password option is added in "Image Capture" window to protect unexpected change of camera resolution.
2. Profile data option is added in the current "Profile" menu.
Every pixel value about Gray, Red, Green, and Blue intensity on the profile line is generated. Data can be exported to Excel or saved as txt file format for the further manipulation.
The video clip in the "DOWNLOADS" shows the updated contents.
The latest Capture Driver( Jan. 28th, 2008) in the same "DOWNLOADS" is required to use together if you have installed old version of Capture Driver.
Removing the previous version first while disconnecting dongle(copy protection electronic key) before installing new version is required.
Please contact us again for any further question or free upgrade of iSolution DT.

Feb 25th, 2008
- Wide computer monitor support




 ÁÖ¿ä Ä«¸Þ¶ó µå¶óÀ̺ê
 iSolution Capture ÇÁ·Î±×·¥






 
  Home | Contact Us | Products | Support | Downloads | Media Manuals | Events | Newsletters